Test start, Yes no, Test1 test2 test3 – Furuno Sc 50 User Manual

Page 61

Advertising
background image

3. MAINTENANCE, TROUBLESHOOTING

3-5

Diagnostic test2

If the heading indication changes randomly when ship is at anchor or does not
change when the ship moves, run the test2 following the procedure below, with
the ship at anchor and satellite signal received.

Note:

Heading is not output during the diagnostic test, and this is communicated

with an appropriate message. After completing the diagnostic test, turn
the power off and on to update heading data.

1. Press the [MENU] key to open the menu.
2. Choose SYS SETUP and then press the [ENT] key.
3. Choose TEST? and then press the [ENT] key.

TEST1

TEST2
TEST3

Test menu options

4. Choose TEST2 and then press the [ENT] key.

TEST START?

(STOP: PWR OFF)

ARE YOU SURE?

YES

NO

Test start prompt

5. Press ◄ to choose YES and then press the [ENT] key.
6. Press the [ENT] key twice. Rate and angle values are 0.0

°

. If the values

increase or decrease markedly (with ship at anchor), suspect rate sensor
trouble. Contact your dealer to request service.

TEST2

RATE
ANGLE

YAW

ROL

PIT

0.0

°

0.0

°

0.0

°

0.0

°

0.0

°

0.0

°

<STOP: PWR OFF>

TEST2 display

7. Turn off the processor unit to quit the diagnostic test2.

Advertising