Safety instructions

Modules with electrostatic-sensitive components

Systems and components that might be damaged by electrostatic discharge
(ESD) are marked with the following label:

Figure 2: ESD label

When you handle components fitted with ESDs, you must observe the following
points under all circumstances:

●

Remove the power plug before installing or removing components
containing ESDs.

●

You must always discharge yourself of static charges (e.g. by touching a
grounded object) before working.

●

The equipment and tools you use must be free of static charges.

●

Only touch the components at the positions highlighted in green (touch
points).

●

Do not touch any exposed pins or conductors on a component.

●

Use a grounding cable designed for this purpose to connect yourself to the
system unit as you install components.

●

Place all components on a static-safe base.

I

You will find a detailed description for handling ESD components in the
relevant European or international standards (DIN EN 61340-5-1,
ANSI/ESD S20.20).