(b)

Control register #1

X©00π is set when the power is turned on or when a CLEAR command is issued for
initialization.

7

0

6

5

4

3

2

1

0

LSB

MSB

Density

0 0¥¥¥

:

Set from the operator panel

0 1 0 0 0

:

Light

0 1 0 0 1

:

Darken more

0 1 0 1 0

:

Somewhat light

and more

0 1 0 1 1

:

0 1 1 0 0

:

Normal

*3

0 1 1 0 1

:

0 1 1 1 0

:

Somewhat dark

0 1 1 1 1

:

Dark

1¥¥¥¥ :

Automatic (*1)

Linedrawing/photograph

0¥ :

Specified from the operator panel

1 0 :

Linedrawing (*2)

11 :

Photograph (*2)

*1 This function is valid for image processing circuit (IPC ¬) option.

When the IPC ¬ option is installed and these bits indicate 1xxxx, the scanner
applies the DTC function, and the function of the image control register and
subwindow control register are not operated.

*2 The scanning speed of ADF (sheets/min) in Linedrawing mode is different from

that of Photograph mode. See Appendix B for more information.

*3 When the control registor #19, bit 0 is ©0π, 8 typs density are sellectable by the

control registor #1, bit 3 to 0.

And when the control registor #19, bit 0 is ©1π, 256 typs density are sellectable
by the control registor #20.

50FH5037E>02

6 $ 9