FUJITSU 50FH5037E-02 User Manual

Page 78

Advertising
background image

(f)

Image control registers #5 and #6

(*1)

7

0

6

0

5

0

4

0

3

1

2

0

1

0

(

LSB)

7

6

5

4

3

2

1

0

(

LSB)

Magnification/vertical magnification (when
each direction zooming is valid)

000011001

25%

to

to

110010000

400%

Vertical/horizontal zooming specification (*2)

0: Same magnification for both direction
1: Different magnification for each

direction

#5

#6

*1 Registers #5 and #6 must be sent consecutively. Registers #5, #6, #7, and #8

must be sent consecutively for different vertical/horizontal magnification.

*2 When the vertical/horizontal zooming specification is set to ™0∫, the horizontal

and vertical magnification is indicated. When this specification is set to ™1∫,
vertical magnification is specified at bit 0 of the register #5 and at all bits of the
register #6.

X©0864π is set when the power is turned on or when the initial status is specified.

Example

How to calculate the output resolution :

f

Control register #1 is X©0Bπ (200 dpi)

f

Image control register #5 and #6 are X©0819π (25%)
Output resolution = 200 dpi ¥ 0.25 = 50 dpi

6 $ 28

50FH5037E>02

Advertising
This manual is related to the following products: