Installation, Installing appliance base assembly – FMI MF42ONE User Manual

Page 7

Advertising
background image

www.fmiproducts.com

125636-01A

7

INSTALLATION

Continued

INSTALLING APPLIANCE BASE ASSEMBLy

Area of Various Standard Round Flues

Diameter

Area

5"

20 sq. inches

6"

29 sq. inches

7"

39 sq. inches

8"

51 sq. inches

Chimney Height Minimum Permanent Flue Opening

6' to 15'

39 sq. inches

15' to 30'

29 sq. inches

Figure 8 - Attaching Damper Clamp

Damper

Damper

Clamp

Damper

Damper

Clamp

Damper

Manufactured Fireplace

Masonry Fireplace

INSTALLING APPLIANCE BASE ASSEMBLY

WARNING: You must secure this appliance

to fireplace floor. If not, appliance will move
when you adjust controls. Moving appliance
may cause a gas leak.

WARNING: If installing in a sunken fireplace,

special care is needed. You must raise the fire-
place floor to allow access to appliance control
panel. This will insure adequate air flow and
guard against sooting and controls being dam-
aged. Raise fireplace floor with noncombustible
material. Make sure material is secure.

Figure 9 - Connecting Incoming Gas Line to Flex Gas Line

Note:
1) Wire connections not

shown for clarity

2) * 1/8" NPT Plugged

Tapping

MAIN

IN

OUT

PILOT

ADJ

PILOT

Pilot Adjustment

Inlet Pressure Tap

Outlet Pressure Tap

Gas Shutoff
Valve

Flexible
Gas Line
Do NOT
Kink

1/2" NPT
Incoming
Gas Line

Set Screw

Installation Items Needed

• hardware package (provided with appliance)
• approved flexible gas hose and fittings provided (if allowed

by local codes)

• sealant (resistant to propane/LP gas, not provided)
• electric drill with 3/16” masonry drill bit
1. Apply pipe joint sealant lightly to male threads of the 1/2

NPT side of gas fitting elbow (provided) and connect to inlet
side of gas control. Remove gas fitting from flexible gas
hose (provided) before connecting to elbow (see Figure
9).

2. Position appliance base assembly in fireplace.
3. Mark screw locations through holes in front panel of base

(see Figure 10, page 8). If installing in a brick-bottom fire-
place, mark screw locations in mortar joint of bricks.

4. Remove appliance base from fireplace.
5. Drill holes at marked locations using 3/16" drill bit.
6. Attach base, through holes in back side panels of base, to

fireplace floor using masonry screws provided in hardware
package (see Figure 10, page 8).

7. Connect to gas supply. See Connecting To Gas Supply,

page 8.