Furuno 1724C User Manual

Page 184

Advertising
background image

7. CUSTOMIZING YOUR UNIT

7-21

DEPTH AREAS LIMIT:

Choose the shallow, medium and deep depths to color according to

depth.

Setting Setting

Range

Default

Setting

DEPTH AREAS LIMIT-SHALLOW

2 m, 5 ft, 1 fa, 1 pb

DEPTH AREAS LIMIT-MEDIUM

9 m, 30 ft, 5 fa, 6 pb

DEPTH AREAS LIMIT-DEEP

0-15000 m
0-49212 ft
0-8202 fa
0-9090 pb

18 m, 60 ft, 10 fa, 11 pb

DEPTH LINES & SOUNDINGS:

Choose where to display depth contours, depth data, etc.

Setting Description

Default

Setting

PLOT/OVERLAY

Shows depth lines and soundings on the plotter and
overlay displays.

PLOTTER

Shows depth lines and soundings on the plotter display.

OFF

Turns off depth lines and soundings.

PLOT/OVERLAY


DEPTH LINES & SOUNDINGS LIMIT:

Chooses the depth range at which to show depth

lines and soundings (depth contours, depth data, etc.)

Setting Setting

Range

Default

Setting

DEPTH LINES AND SOUNDINGS LIMIT-SHALLOW

0 m, 0 ft, 0 fa, 0 pb

DEPTH LINES AND SOUNDINGS LIMIT-DEEP

0-15000 m
0-49212 ft
0-8202 fa
0-9090 pb

305 m, 1000 ft, 167 fa,
185 pb


ROCKS DEPTH LIMIT:

Chooses range for rocks depth display.

Setting Setting

Range

Default

Setting

ROCKS DEPTH LIMIT-SHALLOW

0 m, 0 ft, 0 fa, 0 pb

ROCKS DEPTH LIMIT-DEEP

0-304 m
0-999 ft
0-166 fa
0-184 pb

9 m, 30 ft, 5 fa, 6 pb