Doc No: OMM50000903

Rev: B Page 7 of 65

Subject to contractual terms and conditions to the contrary, this document and all the information contained herein are the confidential and exclusive

property of FMC Technologies, and may not be reproduced, disclosed, or made public in any manner prior to express written authorization by FMC.

Figure 2: L06 – L16 Pump Assembly with No Pinion Shaft (Includes HD & HV)

Choice of straight keyed shaft or
mounting flange for direct coupling
(splined shaft) of hydraulic motors
(shown).

Oil level sight gage allows
remote monitoring of oil level
and condition.

Heavy-duty power ends are machined from a one-
piece gray iron casting for long trouble free life. All
pumps incorporate a reliable splash lube system with
gravity feed return to sump.

Two-bolt cover
clamps or
threaded covers
for easy access
to valves

Abrasion resistant (AR) or disc type
valves feature tough, durable
materials and generous flow areas to
extend service life. Ball type valves
are available for fluids with solids that
will foul conventional valves and
restrict flow.

NPT threaded ports
are standard.

Many piston and liner combinations are offered to
provide maximum service life for each application.
Liner wash is available for extending piston and
liner life.

Integrally cast and
machined feet to provide
rigid and precise mounting

Magnetic drain
plugs remove
tramp iron from
the oil bath.

Fluid ends are designed for years of service
in demanding applications. Standard
materials of construction are cast ductile iron
or nickel aluminum bronze. Fluid end design
allows for very low clearance volumes to
improve both volumetric efficiency and the
pumps ability to prime.

Individually clamped
cylinder covers on
most models allow
easy access for
service needs.

FMC Nameplate

Advertising