7

Program Control

Manual/Auto Dispense

• Each mode provides you access to different features on the liquid crystal

display. Use the Auto/Manual switch to move back and forth from
manual mode to automatic mode.

• In manual mode, you can use the foot pedal to dispense a deposit or bead

“by eye”. You are in manual mode when the Auto/Manual toggle switch
is in the downward position.

• In Automatic Dispense mode, you can set several variables, including

program number, syringe barrel size, deposit volume, dispense rate,
pullback, delay. You are in automatic dispense mode when the
Auto/Manual toggle switch is in the upward position.

Reverse Motion—Drawback

In manual mode, flip the Extend switch, located on the control panel, from
Extend to Retract to engage the motor in reverse direction. This will draw
fluid back into the reservoir stopping any ooze.

Hand Control

In both manual and auto mode, flip the Foot/Hand switch, from Foot to
Hand to operate the dispenser with a finger switch. Finger switches are
sold separately.

Retract Manual Hand

Extend Auto Foot

Power
On/Off

Control
Toggle
Switches

Gun Port

LCD Display

Control
Pad