WARNING

GROUNDING

Before connecting the product to the power line, make sure that the
protective ground terminal of the device is connected to the safety ground
conductor of the mains power cord.

The main power supply plug should only be inserted in a socket outlet
provided with a connected safety ground. The protective action must not
be negated by use of an extension cord (power cable) without a protective
conductor (grounding). Any interruption of the protective (grounding)
conductor or disconnection of the protective ground terminal can make
the device unsafe to use. Intentional interruption is prohibited.

This equipment has a connection between the earthed conductor of the
DC supply circuit and the grounding conductor.

WARNING

WIRING FOR NATIONAL POWER PLUG

A mains power cable according to National Electrical Code (NEC) with
molded IEC socket is supplied with each unit. The specific national
mains power plug should be wired as follows:

Brown lead

Live (phase)

Blue lead

Neutral

Green/Yellow lead

Safety ground.

WARNING

LINE VOLTAGE

Before connecting the product to the power line, make sure the voltage
of the power source matches the requirements of the product, as marked
on the label located near the power connectors.

WARNING

DC POWER SOURCE

The DC power source should be protected with a branch circuit over-
current protection rated at 10Amp, located in the building installation