Laser safety, Aser, Afety – Foundry Networks M2404F User Manual

Page 23

Advertising
background image

Foundry NetIron M2404C/M2404F Metro Access Switches

January 2007

© 2007 Foundry Networks, Inc.

17

2.

Remove the bolts and spring-washers from the grounding posts on the switch’s rear
panel, and clean the metal surface underneath with a dry cloth if necessary.

3.

Apply some anti-oxidant onto the metal surface.

4.

Mount the lug on the two grounding posts, replace the spring-washers and fasten the
bolts. Avoid using excessive torque.

5.

Connect the grounding wire to a reliable ground. If the switch is mounted in a rack, use a
common ground for all devices on the rack, according to your company’s policy.

Laser

Safety

The device is provided with SFP sockets in which fiber optic transceivers may be installed. In
order to meet the safety requirement of Class 1 fiber optic laser emission levels, only fiber optic
transceivers which comply with IEC 60825-1 or IEC 60825-2 and FDA 21 CFR 1040.10 and
CFR 1040.1 must be used.

Advertising
This manual is related to the following products: