To write the backup configuration file, type:

device-name#copy startup-config <IP address> <filename>

<filename> is the file where the configuration file was saved.

Downloading Configuration from Backup Text File

The configuration file can be easily downloaded, using the copy command. Type:

copy tftp://<Server IP address>/<filename> startup-config

<filename> is the file where the configuration file was saved.

NOTE

The copy command uses TFTP protocol for its execution, so prior to using the
copy command, verify that the TFTP Server program is executed by the
addressed computer.

Reloading Factory Defaults Configuration

Use the reload command to reload the factory defaults configuration.

device-name#reload to-defaults

Restore factory setting and Reboot the Switch !

[y/n]: y

Rebooting ...

NOTE

The reload to-defaults command does NOT change the IP address and netmask
of the switch.

Monitoring/Configuring CPU Operating Temperature

Should the temperature reach the configured upper limit, the unit will send an SNMP trap to the
management station. If this occurs, the user is requested to make sure that all unit ventilation
airways are free and disengaged and that the fans are functioning.