4. BASIC SETUP

4-2

To set type of alarm to output

1. Rotate the CH knob (or press up / down arrow key) to choose EXT ALARM

from the ALARM MENU and press the ENT key. The following setting
window appears.

DIST/URG : ON

SAFETY : OFF

ROUTINE : ON

Aleays ON

2. Rotate the CH knob (or press up / down arrow key) to choose an appropriate

option. Alarm is output to external device.

DSTRS/URG: Distress or urgency call output upon receipt.

SAFETY: Safety call output upon receipt.

ROUTINE: Routine call output upon receipt.

3. Press the ENT key.
4. Choose ON or OFF as appropriate and press the ENT key.
5. Press the CANCEL key three times to return to the standby display.