5 - 61

Table 5.12 Contents of SECURITY SET PASSWORD data

Word

Contents

0

Control word

Bit 0 Identifier

0 = Sets a user password.

1 = Sets a master password.

Bits 1 to 7 Reserved

Bit 8 Security level

0 = High

1 = Maximum

Bits 9 to 15 Reserved

1 to 16

Password (32 bytes)

17 to 255

Reserved

Table 5.13

Relationship between combination of Identifier and Security level, and
operation of the lock function

Indentifier

Level

Description

User

High

The specified password is saved as a new user password. The
lock function is enabled after the device is turned off and then
on. LOCKED MODE can be canceled using the user password
or the master password already set.

Master

High

The specified password is saved as a new master password. The
lock function is not enabled.

User

Maximum

The specified password is saved as a new user password. The
lock function is enabled after the device is turned off and then
on. LOCKED MODE can be canceled using the user password
only. The master password already set cannot cancel LOCKED
MODE.

Master

Maximum

The specified password is saved as a new master password. The
lock function is not enabled.