FUJITSU MPD3XXXAT User Manual

Page 21

Advertising
background image

C141-E069-02EN

1 - 6

(3)

Current Requirements and Power Dissipation

Table 1.3 lists the current and power dissipation.

Table 1.3

Current and power dissipation

Typical RMS current (*1) [mA]

+12 V

+5 V

Model

MPD3043

AT

MPD3064/

MPD3084

AT

MPD3108/

MPD3130

AT

MPD3173

AT

All Models

MPD3043

AT

MPD3064/

MPD3084

AT

MPD3108/

MPD3130

AT

MPD3173

AT

Spin up

1500

1900 peak

1500

1900 peak

1600

1900 peak

1600

1900 peak

560

600 peak

20.8

20.8

22.0

22.0

Idle (Ready) (*3)

130

177

205

230

280

3.0

3.5

3.8

4.2

R/W (On Track) (*4)

168

213

240

267

560

4.8

5.4

5.7

6.0

Seek (Random) (*5)

325

350

377

404

544

6.6

6.9

7.2

7.6

Standby

6.5

6.5

6.5

6.5

157

0.9

0.9

0.9

0.9

Sleep

6.5

6.5

6.5

6.5

152

0.8

0.8

0.8

0.8

*1

Current is typical rms except for spin up.

*2

Power requirements reflect nominal values for +12V and +5V power.

*3

Idle mode is in effect when the drive is not reading, writing, seeking, or executing any commands. A portion of the R/W circuitry is powered
down, the spindle motor is up to speed and the Drive ready condition exists.

*4

R/W mode is defined as 50% read operations and 50% write operations on a single physical track.

*5

Seek mode is defined as continuous random seek operations with minimum controller delay.

Typical Power (*2) [watts]

Mode of Operation

Advertising