FUJITSU MPD3XXXAT User Manual

Page 97

Advertising
background image

C141-E069-02EN

5 - 30

Table 5.5

Information to be read by IDENTIFY DEVICE command (1 of 4)

Word

Value

Description

0

X‘045A’

General Configuration *1

1

*2

Number of cylinders

2

X‘0000’

Reserved

3

*3

Number of Heads

4

X‘0000’

Retired

5

X‘0000’

Retired

6

X‘003F’

Number of sectors per track

7-9

X‘000000000000’

Retired

10-19

Serial number (ASCII code) *4

20

X‘0000’

Retired

21

X‘0400’

Buffer size in 512 byte increments

22

X‘0004’

Number of ECC bytes transferred at READ LONG or WRITE LONG command

23-26

Firmware revision (ASCII code) *5

27-46

Model number (ASCII code) *6

47

X‘8010’

Maximum number of sectors per interrupt on READ/WRITE MULTIPLE command

48

X‘0000’

Reserved

49

X‘0B00’

Capabilities *7

50

X‘0000’

Reserved

51

X‘0200’

PIO data transfer mode *8

52

X‘0000’

Retired

53

X‘0007’

Enable/disable setting of words 54-58, 64-70 and 88 *9

54

(Variable)

Number of current Cylinders

55

(Variable)

Number of current Head

56

(Variable)

Number of current sectors per track

57-58

(Variable)

Total number of current sectors

59

*10

Transfer sector count currently set by READ/WRITE MULTIPLE command

60-61

*11

Total number of user addressable sectors (LBA mode only)

62

X‘0000’

Retired

63

X‘xx07’

Multiword DMA transfer mode *12

64

X‘0003’

Advance PIO transfer mode support status *13

65

X‘0078’

Minimum multiword DMA transfer cycle time per word : 120 [ns]

66

X‘0078’

Manufacturer's recommended DMA transfer cycle time : 120 [ns]

67

X‘0078’

Minimum PIO transfer cycle time without flow control : 120 [ns]

68

X‘0078’

Minimum PIO transfer cycle time with IORDY flow control : 120 [ns]

69-79

X‘00’

Reserved

80

X‘001E’

Major version number *14

81

X‘0000’

Minor version number (not reported)

82

X‘346B’

Support of command sets *15

83

X‘4008’

Support of command sets *16

84

X‘4000’

Support of command set/feature extension (fixed)

85

X‘00xx’

Enable/disable Command set/feature enabled. *17

86

X‘000x’

Enable/disable Command set/feature enabled. *18

87

X‘4000’

Default of command set/feature (fixed)

88

X‘xx1F’

Ultra DMA modes *19

89

X‘0000’

Time required for security erase unit completion

90

X‘0000’

Time required for Enhanced security erase completion

91

X‘00xx’

Current advanced power management value

92

X‘0000’

Reserved

93

X‘x000’

CBLID detection results *20

94-127

X‘00’

Reserved

128

X‘xx’

Security Status

129-255

X‘00’

Reserved

Advertising