Mb3773 – FUJITSU MB3773 User Manual

Page 17

Advertising
background image

MB3773

17

EXAMPLE 6: Monitoring Low voltage and Overvoltage Monitoring (with hysteresis)

V

CC

(5 V)

1

2

3

4

8

7

6

5

MB3773

RESET

RESET

CK

GND

Comp. 2

Example : Comp. 1, Comp. 2

: MB4204, MB47393

20 k

R

6

_

+

180 k

R

4

30 k

R

3

5.6 k

R

6

1.2 k

R

1

4.7 k

R

5

Comp. 1

Notes :

Comp. 1 and Comp. 2 are used to monitor for overvoltage while the MB3773 is used to monitor

for low voltage. Detection voltages V

1L

/V

1H

at the time of low voltage are approximately 4.2 V/4.3 V.

Detection voltages V

2L

/V

2H

at the time of overvoltage are approximately 6.0 V/6.1 V.

For the formulas for finding hysteresis width and detection voltage, see EXAMPLE 4.

Use V

CC

(

=

5 V) to power the comparators (Comp. 1 and Comp. 2) in the external circuit shown

above.

Logic circuit

Diode

RESET

0

V

1L

V

1H

V

2L

V

2H

V

CC

+

_

C

T

Advertising