EXAMPLE 9: Reducing Reset Hold Time

V

CC

(

=

5 V)

1

2

3

4

8

7

6

5

C

T

MB3773

RESET

RESET

CK

GND

Logic circuit

(a) T

PR

reduction method

V

CC

(

=

5 V)

1

2

3

4

8

7

6

5

C

T

MB3773

RESET

RESET

CK

GND

Logic circuit

Notes :

RESET is the only output that can be used.

Standard T

PR

, T

WD

and T

WR

value can be found using the following formulas.

Formulas: T

PR

(ms) := 100

×

C

T

(

µ

F)

T

WD

(ms) := 100

×

C

T

(

µ

F)

T

WR

(ms) := 16

×

C

T

(

µ

F)

The above formulas become standard values in determining T

PR

, T

WD

and T

WR

.

Reset hold time is compared below between the reduction circuit and the standard circuit.

(b) Standard usage

C

T

=

0.1

µ

F

T

PR

reduction circuit

Standard circuit

T

PR

:=

10 ms

100 ms

T

WD

:=

10 ms

10 ms

T

WR

:=

1.6 ms

2.0 ms