After tighten the screw, slight pull the wire and confirm whether is it firm or not.

The cover plate must be fixed, and tighten the connection wire, if it is poor installed, that

Install indoor unit

NOTE:

When connecting the electric wire if the wire length is not enough, please contact with

the authorized service shop to buy a exclusive electric wire that is long enough and the

joint on the wire are not allowed.

The electric wiring must be correctly connected, wrong connection may cause spare parts

malfunction.

Tighten the terminal screw in order to prevent loose.

If the earth wire is wrong connection, that may cause electric shock.

the dust, moisture may enter in or the connection terminal will be affected by outside force,

and will cause fire or electric shock.

右后

4.

2.

3.

1.


1.
2.

Install the indoor unit

The piping can be lead out from right, right rear, left

left rear.

When routing the piping and wiring from the left

or right side of indoor unit, cut off the tailings

from the chassis in necessary(Show in Fig.7)

Cut off the tailings 1 when routing the wiring only;

Cut off the tailings 1 and tailings 2 when routing

both the wiring and piping.

Take out the piping from body case, wrap the piping

electric wire, water pipe with tape and pull them

through the piping hole (As show in Fig.8)

Hange the mounting slots of the indoor unit on the

upper tabs of the rear panel and check if it is firm

enough.(As show in Fig.9)

or more from the floor.

Install the connection pipe

Align the center of the piping flare with the relevant valve.

Screw in the flare nut by hand and then tighten the

nut with spanner and torque wrench refer to the

following:

Spanner

Torque

wrench

Piping

Taper nut

Indoor unit piping

Fig.9

Mounting

plate

Fixing hook

Mounting

baord

Right

Right rear

Fig.8

Left rear

Left

Fig.7

Tailing 1

Tailing 2

Finally wrap it

with tape

Gas side piping

insulation

Water drainage pipe

Liquid side

Piping insulation

Gas side pipe

External connection

electric wire
Liquid side piping

Ф6

Ф 9.52

Ф 12

Ф 16

Ф 19

Hex nut diameter

Tightening torque

5.

The water drainage pipe can also be installed on the left of

the indoor-uint.

The height of the installed location should be

8 ft

(lb . ft)

11~14.7

22.8~25.8
36.9~40.6

44.3~47.9
51.6~55.3

Note: First connect pipe to indoor unit, then to outdoor unit. Pay attention not to bending

piping as this may cause damage. Do not overtighten joint nut as this may cause

leakage.