Safety
Important information
Before starting up
V
CAUTION!
●
During installation and before operating the device, observe the 
instructions on environmental conditions for your device (see 
●
If the server has been moved from a cold environment, condensation 
may form both inside and on the outside of the machine. 
Wait until the server has acclimatized to room temperature and is 
absolutely dry before starting it up. Material damage may be caused 
to the server if this requirement is not met.
●
Only transport the server in the original packaging or in packaging 
that protects it from impacts and jolts.
Installation and operation
V
CAUTION!
●
This unit should not be operated in ambient temperatures above 
35°C.
●
If the unit is integrated into an installation that draws power from an 
industrial power supply network with an IEC309 connector, the power 
supply's fuse protection must comply with the requirements for non-
industrial power supply networks for type A connectors.
●
The unit automatically adjusts itself to a mains voltage in a range of 
100 V - 127 V or 200 V - 240 V. Ensure that the local mains voltage 
lies within these limits.
●
This device must only be connected to properly grounded shock-
proof sockets or insulated sockets of the rack's internal power supply 
with tested and approved power cables.
●
Ensure that the device is connected to a grounded shockproof socket 
close to the device.