Important information

Safety

Modules with Electrostatic-Sensitive Devices

Modules with electrostatic-sensitive devices are identified by the following
sticker:

Figure 1: ESD label

When you handle components fitted with ESDs, you must always observe the
following points:

●

Switch off the system and remove the power plugs from the power outlets
before installing or removing components with ESDs.

●

You must always discharge static build-up (e.g. by touching a grounded
object) before working with such components.

●

Any devices or tools that are used must be free of electrostatic charge.

●

Wear a suitable grounding cable that connects you to the external chassis of
the system unit.

●

Always hold components with ESDs at the edges or at the points marked
green (touch points).

●

Do not touch any connectors or conduction paths on an ESD.

●

Place all the components on a pad which is free of electrostatic charge.

I

For a detailed description of how to handle ESD components, see the
relevant European or international standards (EN 61340-5-1,
ANSI/ESD S20.20).