Setting up the server, 2 setting up the server – FUJITSU TX120 User Manual
Page 35

TX120
Operating Manual
35
Hardware installation
Setting up the server
4.2
Setting up the server
Ê
Install the server.
I
Note that the server may be operated in the vertical (see section
“Positioning the server vertically” on page 36
) or horizontal position
(see section
“Positioning the server horizontally” on page 39
).
V
CAUTION!
–
The device must be protected from direct sunlight.
–
The required minimum distances for operation and maintenance
areas must be adhered to.
–
The server must be accessible at the rear for connection to other
devices (e.g. memory subsystem).
–
The mains plug must be accessible easily and safely.
–
To ensure sufficient ventilation of the system, a minimum clear
distance of 200 mm must be provided at the front and the rear of
the server.
Ê
Wire the server. Follow the instructions in the sections
“Notes on connecting/disconnecting cables”
.
Ê
Connect the server to the mains (see section