Hazardgard special features, Control panel exclusive – Friedrich HAZARDGARG R-410A User Manual

Page 10

Advertising
background image

Permanent Split-Capacitor, totally enclosed fan motor

to assure efficient operation even under adverse

electrical conditions. Motor has a special stainless

steel shaft to resist corrosion and a hermetically sealed

overload for arc-free operation.

High capacity compressor with internal hermetically

sealed overload.

Solid-state relay contains transient voltage suppressor

to protect controls against transient voltage spikes.

Provides solid state switches for arc-free operation.

Hot gas bypass low ambient control to permit operation

without freezing at outdoor ambient temperatures as

low as 45

°F (7°C).

Environmentally sealed on-off switch and gold plated

contacts in thermostat for corrosion resistance.

Electrodeposited epoxy primer and alkyd enamel, both

oven-baked for an attractive, long-lasting finish.

Copper tubing/aluminum fin coils.

Galvanized steel cabinet and base pan, all bonderized.

Slide-out chassis for easy installation in window or

through–the–wall.

Extra insulation inside, including completely insulated

plenum chamber for quieter, more efficient cooling.

Entire unit test run in environmental chamber before

crating.

Eight–way air flow control for uniform air circulation.

Condensate drain with exclusive mosquito trap.

15 amp circuit with time-delay fuse required.

Accommodates direct wiring.

Long lasting 3/8” (10mm) thick air filter, germicidally

treated, easily removed for cleaning.

Friedrich Air Conditioning quality has been proven by more than 25 years of successful experience from the Gulf

of Mexico to the searing sands of the Arabian desert.

Function Control (Power)

This switch is a double pole, single throw toggle switch.

ON - Turns everything on.

OFF - Turns everything off.

Temperature Control

The knob at the bottom is the thermostat which is a cross

ambient type used to maintain the desired comfort level.

The thermostat reacts only to a change in temperature at

the bulb location - turn the knob clockwise to set cooler,

counterclockwise for warmer.

Friedrich leads with the first UL Listed Room Air

Conditioners designed to cool living quarters and other

enclosures situated in hazardous locations where specific

volatile flammable liquids or gases are handled or used with

enclosed containers or systems.

Friedrich Hazardgard

room air conditioners are designed to meet the National

Electrical Code, Article 500 requirements for Class

I, Division 2, Groups A, B, C, D Hazardous locations,

and are the only air conditioners UL Listed for this

application. THIS UNIT IS LISTED BY UNDERWRITERS

LABORATORIES FOR USE IN CLASS I, DIVISION

2,GROUPS A, B, C, D HAZARDOUS LOCATIONS.

Operating Temperature Code: T3B.

HAZARDGARD SPeCIAL feATUReS

Control Panel

exclusive

9