Deactivating the auto plotter, Figure 6-1 arp menu, Figure 6-2 arpa display – Furuno 1942 MARK-2 User Manual

Page 39: Target full mark

Advertising
background image

6

-3

3. Select “ARP-10 MENU.”

4. Press the [ACQ/ENTER] key to display

the ARP menu.

[ ARP MENU ]

Select item by omnipad

and press ENTER key.

1.

Display

2 . All Cancel

3 . Vector Ref

4 . Vector Length

5 . History

6 . CPA Set

7 . TCPA Set

8 . Auto ACQ

Off

On

Rel

True

30S IM

3M 6M 15M

30M

Off

15S 30S 1M

2M 3M 6M

Off

0.5 1nm 2nm

3nm 5 nm 6nm

30S

1M 2M 3M

4M 5M 6M 12M

Off

On

Figure 6-1 ARP Menu

5. Select the menu item “1. Display.”

6. Select “On.”

7. Press the [ACQ/ENTER] key.

8. Press the [MENU] key to close the menu.

Deactivating the auto plotter

To deactivate the Auto Plotter;

1. Open the “ARP-10 MENU.”

2. Select the “1. Display.”

5. Select “Off.”

6. Press the [ACQ/ENTER] key.

7. Press the [MENU] key to close the menu.

HDG 234.5

°

SP

HU

8

NM

2

TRAIL

30M

ZOOM

ES1

AUTO

25:38

G (OUT)

VRM

0.048NM

0.100NM

13.5 R

°

0.142NM

A/C

AUTO

EBL

345.6 R

23.0 R

°

°

TRUE VECTOR

15 MIN

BEARING 42.5

°T

RANGE 5.36 NM

CPA 2 NM

COURSE 287.8

°T

SPEED 12.5 KT

TCPA 12:35

Auto Plotter
Data Area

Target under auto tracking but not
selected for cursor data reading

Target selected
for data reading

Auto
Acquisition
Area

Threatening
target

Lost Target

AUTO TARGET
FULL

Target Full
Mark

Figure 6-2 ARPA display