Furuno 1942 MARK-2 User Manual

Page 47

Advertising
background image

SP - 3

Water temperature:

MTW>MDA

Time: ZDA

Cross track error:

RMB>XTE>APB

*1: calculate by magnetic drift.

(7) Output Data

NMEA0183 (Version1.5/2.0), RS-422

TLL (target data) and RSD

5. ENVIRONMENTAL CONDITION

(1) Ambient Temperature

Scanner Unit: -25

°C to +70°C

Display Unit: -15

°C to +55°C

(2) Relative Humidity

95 % or less at +40

°C

(3) Waterproofing

Scanner Unit: IPX6

Display Unit: IPX4

6. POWER SUPPLY & POWER CONSUMPTION

(1) Power Supply

12-32 VDC (10.8 to 41.6 VDC)

(2) Voltage and Current

24rpm: 12 VDC/7.8A, 24VDC/3.9A, 32VDC/2.9A (100 kt)

48rpm: 12 VDC/8.8A, 24VDC/4.4A, 32VDC/3.3A (70 kt)

(3) Power Consumption

24rpm: 70 W to 90 W (100 kt)

48rpm: 85 W to 105 W (70 kt)

7. DIMENSIONS AND MASS

See the Outline Drawings

8. COATING COLOR

(1) Display Unit

Panel: N3.0

Chassis:

2.5GY5/1.5

(2) Scanner Unit

N9.5

9. COMPASS SAFE DISTANCE

(1) M1932M2

Display Unit

Standard: 1.1 m

Steering: 0.8 m

Scanner Unit

Standard: 1.0 m

Steering: 0.8 m

(2) M1942M2

Display Unit

Standard: 0.75 m

Steering: 0.6 m

Scanner Unit

Standard: 1.1 m

Steering: 0.8 m

Advertising
This manual is related to the following products: