background image

14

3.2

Replacing the Fuse

The fuse (2A) inside the FA-30 protects it from overcurrent and equipment fault. If the
unit cannot be powered, that is, the PWR (power) LED is off, the fuse may have blown.
If this happens, turn off the power to the FA-30, open the cover and check the fuse. If
the fuse has blown, find out the reason before replacing it. If it blows again after re-
placement, contact a FURUNO agent or dealer for advice.

3.3

Troubleshooting

The troubleshooting table below provides typical operating problems and the means
to restore normal operation. If you cannot restore normal operation, do not attempt to
check inside the receiver; there are no user serviceable parts inside the receiver.

Part

Type

Code No.

Fuse (2A)

FGMB AC125V 2A PBF

000-157-479-10

Troubleshooting table

Symptom

Problem

Remedy

Receiver cannot be
powered.

Fuse inside the receiver may
have blown.

Replace the fuse.

Cannot receive.

• VHF antenna may have

loosened.

• Antenna or its cabling may be

damaged.

• Rx channel is malfunctioning.

• Check if the antenna is firmly

fastened.

• Check the antenna and its

cabling for damage.

• Confirm the channel setting.

WARNING

Use the proper fuse.

Use of a wrong fuse can result in damage
to the equipment and cause fire.