Instructions for re-orienting air inducer – Fedders FV95A090 User Manual

Page 11

Advertising
background image

Instructions for Re-orienting Air Inducer

This furnace comes assembled ready for left side or vertical

venting. Rotate the inducer 180 degrees to exit the right

hand side.
1. Disconnect inducer wire connections.
2. Remove pressure switch hoses.
3. Remove pressure switches.
4. Remove 4 inducer screws
5. Remove inducer.
6. Reverse the bands on the rubber drain coupling so the

screws are accessible if necessary. (Do not reverse the

drain coupling.) Confirm that directional arrows on

drain coupling point away from inducer.

7. Remove the appropriate knock out.
8. Reinstall the inducer in the correct orientation with 4

screws removed in step 1.

9. Reinstall the pressure switches so that the switches and

hose is above the heat exchanger drain.

10. Complete the external venting as installation requires.
11. Rotate the drain coupling so the drain holes are angled

downward and tighten coupling bands.

12. Tighten the vent clamp and secure in place using the

screws provided.

FIGURE A : RIGHT INDUCER POSITION

FIGURE B : LEFT INDUCER POSITION

SUGGESTED METHOD FOR
SUSPENDING HORIZONTAL FURNACE

ALLOW ENOUGH ANGLE
IRON OVERHANG TO
PERMIT OPENING THE
BLOWER DOOR

3/8 INCH THREADED ROD
2 INCH ANGLE IRON
JAM NUTS
LOCK WASHER
FLAT WASHER

SUPPLY AIR PLENUM

RETURN AIR PLENUM

SUSPENDED INSTALLATION

INSTALLATION POSITIONS
Non-Suspended Installation

Maintain clearances to combustibles as outlined in Table 2

on page 6. The furnace must be supported in such a way

as to not allow twisting or sagging of the cabinet.

Horizontal Suspended Installation

or left position by field fabricated a cradle of angle iron and

threaded rod. Secure the furnace with 2 inch minimum

slotted angle or equivalent, as shown in figure below. The

furnace must be supported in such a way as not to allow

twisting or sagging of the cabinet. Position the supports so

as not to interfere with accessing the burner and blower

compartments.

The furnace may be suspended in either the horizontal right