Clearances, Important, Figure 2: dimensions table 3: dimensions – Fedders FV95A090 User Manual

Page 8: Danger, Table 2: clearances to combustibles

Advertising
background image

G

A

C

G

B

F

E

D

J

L

L

K

1

DIMENSIONS (Inches)

MODEL
INPUT

WIDTH

DEPTH

HEIGHT

SUPPLY

AB

C

F x G

RETURN

SIDE

BOTTOM

D x E

J x K

L

H

1

Vent outlet 4”

- Use reducer fittings.

2

Two return air openings required

54,000

72,000

90,000

108,000

54,000

72,000

90,000

108,000

17.5

20.5

20.5

24.5

14 x 22

16 x 19

3/4

2

2

2

2

14 x 22

19 x 19

3/4

14 x 22

19 x 19

3/4

14 x 22

23 x 19

3/4

VENT

29

29

29

29

40

40

40

40

16.5 x 19

19.5 x 19

19.5 x 19

24 x 19

FIGURE 2: DIMENSIONS

TABLE 3: DIMENSIONS

CLEARANCES

Table 2 provides the certified clearances to combustibles.

DANGER

THE AREA AROUND THE FURNACE MUST BE KEPT CLEAR
AND FREE OF ALL COMBUSTIBLE MATERIALS INCLUDING
GASOLINE AND OTHER FLAMMABLE VAPORS AND
LIQUIDS.

THE HOMEOWNER SHOULD BE CAUTIONED THAT THE
FURNACE AREA MUST NOT BE USED AS A BROOM
CLOSET OR FOR ANY OTHER STORAGE PURPOSE.

UPFLOW FURNACES ARE DESIGN CERTIFIED FOR
INSTALLATION ON COMBUSTIBLE FLOORS. THIS SHALL
BE INTERPRETED AS A WOOD FLOOR ONLY.

THE FURNACE MUST NOT BE INSTALLED DIRECTLY ON
CARPETING, VINYL TILE, OR OTHER COMBUSTIBLE
MATERIAL EXCEPT WOOD. INSTALLATION ON
COMBUSTIBLE MATERIAL CAN RESULT IN FIRE, CAUSING
PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

DANGER

COMBUSTIBLE MATERIAL MUST NOT BE PLACED ON OR
AGAINST THE FURNACE JACKET.

PLACEMENT OF COMBUSTIBLE MATERIALS ON, AGAINST
OR AROUND THE FURNACE JACKET CAN CAUSE AN
EXPLOSION OR FIRE RESULTING IN PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.

0"

0"

0"

LO

OK

IN

G

AT

UN

IT

AS

IN

ST

AL

LE

D

TABLE 2: CLEARANCES TO COMBUSTIBLES

See the appliance rating plate affixed to the
furnace for specific model number, serial
number and clearance to combustibles
information.

This furnace requires a minimum of 24-inches of front
clearance for service purposes. For this purpose, service
clearance takes precedence over clearance to
combustibles.

IMPORTANT

0.5"

0.5"

0.5"

0" *

0" *

0" *

0" 0"

1" **

0" ***

0" ****

0"

UPFLOW

COUNTERFLOW

HORIZONTAL

TOP
PLENUM

TOP/BOTTOM

PLENUM SIDES

UNIT FRONT

UNIT BACK

UNIT SIDES

UNIT BASE

UNIT FLUE PIPE

ENCLOSURE

1"

1"

2.5"

1"

2"

0"

0"

0"

0"

CLOSET

CLOSET

CLOSET

ALL DIMENSIONS IN INCHES

* 24" REQUIRED FOR SERVICE

** SUPPLY AIR END / RETURN AIR END

*** CERTIFIED FOR CLOSET INSTALLATION ON COMBUSTIBLE FLOORING

**** CERTIFIED FOR INSTALLATION ON COMBUSTIBLE FLOORING ONLY WHEN INSTALLED

ON SPECIAL BASE PART #30476

6