Installing countertop dispensers

1. Position dispenser in desired location, mark dispenser

outline on counter and remove dispenser.

2. Drill four 3/8" (5mm) holes in counter (Fig. 2) to

anchor dispenser to counter.

Follett countertop dispensers can have any or all

utilities run directly through counter or out rear of
dispenser. For dispensers with any utilities exiting
through counter, make counter cut-out as shown
in Fig. 2.

3. If ice transport tube will exit out rear of dispenser,

remove ice transport tube knock-out (Fig. 5G) from
rear of dispenser.

Note: Utility connections can be accessed through

front of dispenser by removing stainless steel splash
panel on front of dispenser, or by removing access
panel (Figs. 4, 5) on back of dispenser.

4. If any electric utilities or water line will be connected

through rear of dispenser, remove utility knock-out
(Fig. 5H) from rear of dispenser and install supplied
protective grommet.

5. If power is to be supplied through counter cut-out,

complete steps 6-9. If power is to be supplied through
rear of dispenser, proceed to step 10.

6. Temporarily remove rear access panel (Figs. 4, 5)

from rear of dispenser.

7. Loosen junction box mounting screws. Lift junction

box and power cord up until cord and mounting
screws clear notches on rear panel of dispenser.
Remove Phillips head screws from right side of
junction box.

8. Rotate junction box 90 degrees so that screw holes

on right side of junction box align with holes on rear
dispenser panel. Resecure junction box to dispenser
using Phillips head screws.

9. Place power cord inside dispenser and replace

access panel (Figs. 4 and 5) on rear of dispenser.

Note: For dispensers installed with utilities connected

through rear of dispenser, it may be easier to make
preliminary connections before dispenser is set in
place.

10

24.5"

(622mm)

23.75"

(603mm)

6.54"

(167mm)

17.375"

(441mm)

21.375"

(543mm)

3/8"

12.25"

(311mm)

.5" (13mm)

1.625" (41mm)

.5" (13mm)

9" X 14" (227mm x 356mm)

DRAIN PAN

CUT OUT

Fig. 2 – Counter cut-out, all models

(J) 3/8" FPT
water inlet

(L) alternate 3/4"
dispenser drain
location

drain pan

(K) 3/4" FPT
dispenser drain

Dispensers with top mount icemakers cannot be mounted on legs. They must be bolted to counter.
Use gloves when lifting icemaker to protect hands from sheet metal edges.

!

Fig. 3 – Top view, dispenser plumbing connections
countertop and wall mount units with drain pan

Advertising