Troubleshooting sensorsafe board and sensors – Follett 110CT400A/W User Manual

Page 19

Advertising
background image

Troubleshooting SensorSAFE board and sensors

Board guide

LEDs, when illuminated, indicate the following:

PWR (board power)

CLN

(cleaning, no dispensing cycle)

ICE

(ice dispensing activated)

WTR (water dispensing activated)

Terminals:

L1

(incoming power, hot)

L2

(neutral terminals)

WTR (power terminal for water solenoid)

SOL

(power terminal for dispense gate

solenoid)

not

used

WM

(power terminal for wheel motor)

CLN

(terminals for clean cycle switch)

Action

Check LEDs on control
board

Place cup under drop
zone

LED Status

PWR

CLN

ICE/WTR

OFF

OFF

OFF

ON

ON

OFF

ON

OFF

OFF

ON

OFF

ON

Solution

Check circuit breakers and power switch; restore
power or replace defective switch

Depress clean switch located under left side of front
cover to return board to normal operation

Troubleshoot appropriate lens/sensor and replace if
required (see Lens/Sensor Troubleshooting below)

Verify power on appropriate output terminal
(WTR SOL or WM) on control board and replace
board if required; if board tests okay, troubleshoot
appropriate dispenser component

Problem: Does not dispense ice or water

Action

Check LEDs on control
board

LED Status

PWR

CLN

ICE/WTR

ON

OFF

ON

ON

OFF

OFF

Solution

Troubleshoot appropriate lens/sensor and replace if
required (see Lens/sensor troubleshooting below)

If there is power on any output terminal (WTR, SOL
or WM) on control board, replace board

Remove lens protective cover; adjust funnel so water
doesn’t drip down lens or behind splash panel

Problem: Dispenses ice or water continuously