Installation procedures

Installing freestanding dispensers

1. Carefully tip dispenser back to expose underside and block up in place.

2. Remove legs from shipping box (taped to drain pan of dispenser) and screw into dispenser bottom, taking care to seat

legs securely against underside of dispenser.

3. Position dispenser in desired location and adjust legs to level in both directions.

4. Connect water supply to 3/8" FPT fitting on back of dispenser (Fig. 1A).

5. Remove 3/4" dispenser drain line plug from back of unit and discard. Connect separate drain lines to 3/4" FPT

dispenser drain fitting and 3/4" MPT icemaker drain fitting on back of dispenser (Fig. 1B and 1C.)

6. Run drain lines to wall or floor drain. Provide an air break between the drain lines and drain. If icemaker drain fitting is

below an intended wall drain, a condensate pump must be used.

7. If icemaker is water-cooled, connect water-cooled condenser supply line to 3/8" FPT condenser inlet fitting on back of

dispenser (Fig. 1D).

Note: Do not run condenser supply water through icemaker water filter system.

8. Connect condenser drain line to 3/8" FPT condenser outlet fitting on back of dispenser (Fig. 1E).

Important: Do not connect condenser drain line to any other drain lines.

9. Plug dispenser into 20 amp rated NEMA 5-20 wall socket.

10. Remove front cover of base section by removing two screws at bottom corners of cover. Allow cover to drop

approximately 3/8" (5mm) and pull forward.

11. Turn on water supply and check that water level in float reservoir (when full) is within 1/4" (6mm) of mark on side of

reservoir and that float moves freely. Check for leaks.

Before you begin

All dispensers must be installed level in both directions to ensure proper operation

Required ventilation and recommended service clearances:

• Countertop models with Satellite-fill icemaker (110CR400A/W) — none. 12" (305mm) at top recommended for service.

• Countertop models with integral icemaker (110CT400A/W) — 6" (153mm) at top. 6"(153mm) each side recommended

for

service.

• Freestanding models (110FB400A/W) — 4" (102mm) at rear. 12" (305mm) at top recommended for service.

All countertop dispensers provide the option of taking utilities out the bottom or back of the dispenser. See counter

cutout on page 10 (Fig. 2) for bottom exiting utilities on units with and without drain pans. For installations where utilities will exit
through back of dispenser, refer to back view drawings.

SensorSAFE™ dispensers are shipped with a plastic, protective film on sensor lenses. For proper operation, plastic

film must be removed after installation.

8

Do not tilt unit further than 30° off vertical.

!