Venting installation – FMI S42 User Manual

Page 6

Advertising
background image

www.fmiproducts.com

111099-01L

6

Figure 6 - Lineal Gain

LINEAL GAIN

PART NO.

DESCRIPTION

GAIN

42"

Fireplace

44"

12-8DM

12-8HT

Pipe Section

10

5

/

8

"

18-8DM

18-8HT

Pipe Section

16

5

/

8

"

24-8DM

24-8HT

Pipe Section

23

5

/

8

"

36-8DM

36-8HT

Pipe Section

34

5

/

8

"

48-8DM

48-8HT

Pipe Section

46

5

/

8

"

RT-8DM Round Termination

6

7

/

8

"*

RTL-8DM Round Termination

7

3

/

4

"*

RTT-8DM Round Termination

with Slip Section

6

7

/

8

" to

23

1

/

8

"*

RTTL-8DM Round Termination

with Slip Section

8

1

/

2

" to

21

1

/

2

"*

ET-8DM

Square Chase-Top

12"*

ETO-8DM Square Chase-Top

with Mesh

12"*

ETL-8DM Square Chase-Top

with Slip Section

7" to 15"*

ETLO-8DM

Square Chase-Top

with Mesh & Slip

Section

12" to

25

1

/

2

"*

* The lineal gain for the terminations is mea-

sured to the flue gas outlet height.

Hemmed

End

8" Stainless

Inner Pipe

12

3

/

8

" Galvanized

Outer Pipe

ASSEMBLY AND INSTALLATION OF

DOUBLE WALL CHIMNEY SYSTEM

Each double wall chimney section consists of

a galvanized outer pipe, a stainless steel inner

flue pipe and a wire spacer. Pipe sections must

be assembled independently as the chimney

is installed. When connecting chimney directly

to fireplace, the inner flue pipe section must be

installed first with lanced side up. The outer

pipe section can then be installed over the flue

pipe section with hemmed end up. Press down

on each pipe section until lances securely

engage hem on fireplace starter. The wire will

assure the proper spacing between inner and

outer pipe sections.

VENTING INSTALLATION

OPTIONAL OUTSIDE AIR KIT

(MODEL AK4/AK4F)

The installation of an outside air kit should

be performed during the rough framing of

the fireplace due to the nature of it's location.

Outside combustion air is accessed through

a vented crawl space (AK4F) or through a

sidewall (AK4).

CAUTION: Combustion air

inlet ducts shall not terminate

in attic space.

Figure 5 - Outside Air Kit

Secure to Collars with Metal Tape,

Screws or Straps (Min. of 1/4" x 20"

in size)

Air Inlet

Location

Must Allow

For Bushes

or Snow

Vent Hood

Required for

Wall Installation

Air Inlet

Eyebrow

Vented Crawl Space

(Check Local Codes

Before Installing in a

Vented Crawl Space)

CHIMNEY PIPE

The FMI PRODUCTS, LLC chimney system

consists of 12", 18", 24", 36" and 48" snap-

lock, double-wall pipe segments, planned

for maximum adaptability to individual site

requirements. Actual lengths gained after fit-

ting overlaps must be taken into consideration

(lineal gain) and are given in the lineal gain

chart (see Figure 6). Lineal gain is the actual

measurable length of a part after two or more

parts are connected. For Canada, use chimney

parts designated "HT".

WARNING: The opening in

the collar around the chimney at

the top of the fireplace must not

be obstructed. Never use blown

insulation to fill the chimney

enclosure.