Venting installation – FMI S42 User Manual

Page 8

Advertising
background image

www.fmiproducts.com

111099-01L

8

VENTING INSTALLATION

Continued

Figure 9 - Elbow Offset

B

A

Screws

FIRESTOP SPACERS (FS-8DM)

Firestop spacers are required at each point

where the chimney penetrates a floor space.

Their purpose is to establish and maintain

the required clearance between the chimney

and the combustible materials. When the pipe

passes through a framed opening into a living

space above, the firestop must be placed onto

the ceiling from below as shown in Figure 10.
They also provide complete separation from

one floor space to another or attic space as

required by most codes. When the double wall

pipe passes through a framed opening into an

attic space, the firestop must be placed into an

attic floor as shown in Figure 11.

Figure 10 - Firestop Spacer with Living

Space Above Ceiling

Figure 11 - Firestop Spacer with Attic

Space Above Ceiling

Existing

Ceiling

Frame

Firestop

Spacer

Screws or

Staples

(Min. of 8)

Firestop

Spacer

Screws or Staples

(Min. of 8)

PENETRATING ROOF

To maintain a 1" clearance to the pipe on a

roof with a pitch, a rectangular opening must

be cut.
1. Determine the center point through which

the pipe will penetrate the roof.

2. Determine the center point of the roof.

Pitch is the distance the roof drops over

a given span, usually 12". A 6/12 pitch

means that the roof drops 6" for each 12"

one measure horizontally down from the

roof rafters.

3. Use the roof opening chart (Figure 12,

page 9) to determine the correct opening

length and flashing required.

4. Remove the shingles around the opening

measured. Cut out this section.

5. Add the next sections of the pipe until the

end penetrates the roof line. Check to see

that the proper clearances are maintained.

Extend chimney by adding sections of

double wall pipe until pipe is minimum of

30" above the highest point of the roof cut-

out. Termination and chimney must extend

a minimum of 36" above the highest point

where it passes through the roof.

Existing

Ceiling

Frame

Figure 8 - Ceiling Support Pipe

12S-8DM

2" Min.

Straps

Straps

Straps

Straps

Detail A

Return Elbow

Detail B

Angle Firestop

See Detail A

See Detail B