1.3.4 Replacing the Pressure Regulator or Solenoid Valve

1. Drain the cookpot and disconnect the cooker from the electrical power supply. Turn off or

disconnect the water supply to the cooker.


2. Disconnect the solenoid leads at the push-on connectors. Disconnect solenoid and regulator

subassembly at the compression fittings on the water lines running to and from these
components. Remove the two screws in the mounting bracket and remove the solenoid and
regulator subassembly from the unit. (NOTE: If the cooker is not equipped with the optional
Autofill feature, the cookpot water tube will be connected directly to the regulator and there will
be no solenoid valve.)

Remove the two

screws at the

bottom of this

bracket to

dismount the

solenoid and

regulator sub-

assembly.

The incoming water line will be connected

to the nipple at the inlet side of the

regulator using some type of field

connection fitting. Whatever type fitting is

used, disconnect the regulator at this point.

Disconnect the water tube
at this compression fitting.

Solenoid Valve

GSMS with Autofill Configuration

GBC/GC with Autofill Configuration

Disconnect the water
tubes at these
compression fittings.

Solenoid Valve

Remove the two screws

at the bottom of this

bracket to dismount the

solenoid and regulator

sub-assembly.

3. If replacing the regulator, adjust the replacement regulator output pressure to not more than 40

PSI (28.15 kg/cm

2

)

before installation in the cooker.


4. Recover the fittings from the failed component (regulator or solenoid valve) and install them on

the replacement, using thread sealer on all connections.


5. Reverse Steps 1 and 2 to complete the procedure, being sure to apply thread sealer to all

connections.

1.3.5 Replacing the Water Faucet

1. Drain the cookpot and disconnect the cooker from the electrical power supply.

NOTE:

Refer to the illustration at the top of Page 1-6 for the following steps.

2. Turn off the water supply to the cooker and disconnect the incoming water lines where they

attach to the stubs at the rear of the cooker.


3. Remove the two screws securing the access panel in place and remove the panel.

4. Disconnect the water supply line at the compression fitting where it attaches to the water inlet

manifold. Remove the screws from the faucet mounting plate and lift the faucet assembly from
the unit.

Advertising
This manual is related to the following products: