4. INSTALLATION

29

Remarks on installation

• Turn off the engine and anchor the boat

while installing the equipment.

• Install the transducer in the engine room.
• Except for installing the transducer to the

bottom of hull, do not turn on its power so it
may be damaged.

Choosing the mounting location

• The mounting location should be where the

hull is of single-hull thickness and is void of
air or flotation materials other than solid
fiberglass between the transducer face and
the water.

• The mounting location is between 15 to 50

cm from the centerline of the hull.

• Do not place the transducer over hull struts

or ribs which run under the hull.

• Avoid a location where the rising angle of

the hull exceeds 15

°

, to minimize the effect

of the boat's rolling.

• You will finalize the mounting location

through some trial and error. The proce-
dure for this is shown later.

Inside-hull transducer mounting location

Attaching the transducer

1. Clean the transducer face to remove any

foreign material. Lightly roughen the trans-
ducer face with #100 sandpaper. Also,
roughen the inside of the hull where the
transducer is to be mounted.

2. Clean the transducer face again to remove

scourings.

3. Warm the silicone sealant to 40

°

C before

usage to soften it. Coat the transducer face
and mounting location with silicone
sealant.

Coating transducer face with silicone sealant

4. Press the transducer firmly down on the

hull and gently twist it back and forth to
remove any air which may be trapped in
the silicone sealant.

Checking the installation

1. Connect the battery to the display unit.
2. Turn on the display unit.
3. Rotate the MODE knob to choose single

frequency (LF: 50 kHz or HF: 200 kHz).

4. Press the GAIN knob to open the Auto

Gain setting window.

5. Press the GAIN knob

to choose Off and

press the

ENTER

key

.

6. Rotate the

GAIN

knob

to

set the gain to "5".

7. Press the RANGE key to open the Range

setting window.

8. Use

X

to choose Manual.

9. Press the RANGE key continuously to set

the range to 10 meters (feet) and press the
ENTER

key.

10.If the bottom is displayed in reddish brown

and the depth indication appears, the
mounting location is suitable. Go to "Final
preparation."

11.If the bottom is not displayed in reddish

brown, the mounting location may be
unsuitable. Do the following:

a)Press the

/BRILL

key to turn off the

power.

50 cm

50 cm

15 cm

15 cm

1/3

1/2

Transducer
mounting
location

Centerline

Transducer

Silicone
Sealant

Hull

Silicone
Sealant

Advertising