4. INSTALLATION

35

How to fix fuse holders

Establishing the ground

The ground wire (1.25 sq or more, local
supply) should be as short as possible. The
signal line ground is isolated from the chassis
ground, however the power line is not insu-
lated. Therefore, when connecting eternal
equipment having positive ground, do not
ground the signal line to the chassis. If exces-
sive noise shows on the screen, the ground
may be inadequate. In this case, attach a
steel plate measuring 20 cm by 30 cm on the
outside of the hull to provide a ground point.
Connect the ground wire there. Use a
"closed" type lug (

) to make the connec-

tion at the display unit. Do not use an "open"
type lug (

).

Optional equipment

Power connector

The power supply port is commonly used for
connection of external equipment such as a
GPS receiver or wind indicator. Refer to the
interconnection diagram to connect cables.

Pin assignment (front view)

Water temp/speed sensor

Connect the optional water temp/speed
sensor to the XDR port with the optional con-
version cable (Type 02S4147) as shown
below.

Connection of conversion cable 02S4147

Optional transducer

The optional matching box (Type: MB-1100,
Code No.: 000-041-353) is required to con-
nect the optional transducers 50B-6, 50B-6B,
200B-5S, 50/200-1T.

Matching box MB-1100, cover removed

Connector

Color

Remarks

1

TD-A

WHT IEC61162-1/

NMEA0183

2

TD-B

BLU

3

RD-A

YEL

IEC61162-1/
NMEA0183

4

RD-B

GRN

5

TEMP-IN

BRN

Temperature
analog input

6

TEMP-IN-0V

ORG

7

DC-P-IN (+)

RED

Power input
12-24 VDC

8

DC-M-IN (-)

BLK

9

NC

-

10

SHIELD

-

Power supply lines
(red and black)

Fuse holder

Cable tie

1

2

3

4

5

6

7

8

9

10

Tape connectors with
vulcanizing tape
and then vinyl tape
to waterproof them.
Bind tape ends with
cable ties to prevent
tape from unraveling.

Connect to XDR port
at rear of display unit

MJ-A10SPF

MJ-A10SRMD

MJ-A6SRMD

From
transducer

From
sensor

Connect 10P
connector to
XDR port on
rear of
display unit.

Green
(shield)

Transducer

50B-6/6B

200B-5S

50kHz

200kHz

SHIELD

BLK

RED

TB2

1

2

3

4

5

J2 J1

WHT

3

2

1

BLK

TB1

02P6348

Detach grommet;
attach cord lock.

Jumper block setting

J2: No output reduction (default)

J1: Output reduction

BLK

RED