Standard maintenance and trouble shooting

Cleaning of the spray head

Any deposits which may accumulate on the nozzle can be removed by simply running

a finger over the rubber extrusions and then running the water for a few seconds. In

extreme cases this step may have to be repeated.

Replacing the Cartridge

1. Shut off the water supply to the faucet.

2. Open the faucet briefly to relief any pressure inside the faucet.

3. Move the faucet handle to the “OFF” position.

4. Use a the provided allen key to loosen the set screw which is accessible from the back

of the handle.

5. Lift the handle from the cartridge.

6. Find the small notch at the base of the chrome ring cap and carefully pry up against

this to remove the cap.

7. Remove the brass retaining ring.

8. Lift out the cartridge.

9. Ensure that the seats and O-rings are in good condition.

10. Remove potential mineral deposits from inside the faucet body.

11. Install the new cartridge so that the central pivots fit into the corresponding seats.

12. Re-assemble faucet in reverse order.

13. Test for leakage.