6 heading alignment, 7 setting output data, Caution – Furuno PG-1000 User Manual

Page 13

Advertising
background image

6

AUTO

TRUE

CALIB STATUS

: On

: Blinking

Above range of
magnetic sensor

Causes

Results of correction

Remedy

Magnetic field
distortion

Turning error

;;

;;

Follow the
procedure in
above from step
2 after the
replacement of
unit.

;

;

;;

;;

;;

;

;;

;;

;;

Follow the
procedure in
above from step
2 after the
replacement of
unit.

Follow the
procedure in
above from step
2.

Figure 13

Note: Correction can also be done at Remote
Display DD-2000. See the Operator's Manual
for the DC-2000.

1.6

Heading Alignment

Heading alignment is required when sensor
heading is different from actual heading.

This alignment must be done using magnetic
heading (default setting).

CAUTION

CAUTION

Turn off the autopilot before aligning
heading.

The autopilot may turn the rudder suddenly.

Procedure

1. Press the [-] and [+] keys together more than

two seconds. All LEDs go off.

AUTO

TRUE

CALIB

STATUS

: Off

Figure 14

Note: Complete the next step within 10 sec-
onds, otherwise normal operation is restored.

2. Set difference between sensor heading (out-

put) and actual heading with the [+] or [-]
key. For example, the hading output by the
sensor is 70

°

and the actual heading is 75

°

.

Therefore, the difference is +5

°

. Press the

[+] key five times to set +5

°

. Each time the

[+] key is pressed the LEDs light as shown
in Figure 14.

AUTO

TRUE

CALIB STATUS

: On

: Off

+1

°

+2

°

+3

°

+4

°

+5

°

+6

°

+7

°

Repeat

Figure 15 LED state and pressing of [+] key

1.7

Setting Output Data

Setting output interval

The deffault setting is 100 ms.

1. Disconnect the power connector from the

sensor.

2. Reattach the connector to the sensor while

pressing the [+] key. The PG-1000 is pow-
ered on, and the current output interval is
shown by the LEDs.

AUTO

TRUE

CALIB

STATUS

: On

: Off

100ms

200ms

1s

2s

Figure 16 LED state and output interval

Advertising