2 selecting mounting location – Furuno PG-1000 User Manual

Page 9

Advertising
background image

2

-

+

BOW

12-24 VDC

NMEA

AD10

-

+

Å~

Sensor (top view)

Grounding

Black

Red

12-24 VDC

Figure 2 Battery connections to PG-1000

3. Turn the ship's mains switch on.

This sensor doesn't have power switch.

;;

;;

AUTO

TRUE

CALIB

STATUS

: On

: Blinking

: Off

: Status depends on settings.

;

;

About two minutes later

Figure 3 LEDs at power on

4. Confirm that the STATUS LED blinks.

Two minutes later it will light. If STATUS
LED doesn't blink and then light, suspect
sensor error. Reset power.

AUTO

TRUE

CALIB

STATUS

: On

: Status depends on settings

: Off

error

normal

Figure 4

1.2

Selecting Mounting
Location

The PG-1000 must be indoor on the horizon-
tal plane.

When selecting a mounting location, keep in
mind the following points:

• The ambient temperature must be between

-15

°

C and 55

°

C.

• Vibration at the mounting location should

be minimal.

• Install the sensor as far as possible from

power cable, ferrous materials.

• Install the sensor ship's center of gravity.

• Align the bow mark with the ship's bow on

the fore-and-aft-line.

1. Tentatively select the mounting location. Do

not fix it yet.

Ship's bow

Bow mark

Figure 1 PG-1000

2. Connect the PG-1000 to the battery as

shown in right.