12. Thread the new probe wire through the

hole in front of the fryer. The probe
assembly should be oriented in the same
manner as the probe being replaced. Place
the new probe assembly onto the element,
and ensure that the probe extends 1”
beyond the front of the bracket before
securing the bracket. Also ensure that the
springs are on each probe under each
bracket.


13. Apply Loctite PST567 sealant to

replacement threads.


14. Screw the replacement probe into the

frypot and tighten 170-180 inch-pounds
torque. DO NOT OVERTIGHTEN.


15. Reattach the connector and reassemble in

reverse order.








1.11 Replace Heating Elements inside Frypot

1. Perform Procedure 1.10, Replace

Temperature Probe, Steps 1-9.


2. Remove the four screws from the two

brackets in the rear of the frypot that
secure the element to the frypot.


3. Remove wires from the elements by

loosening and removing the nuts.


4. Remove element using an open-end

wrench or other suitable tool to loosen the
compression fitting.




5. Gently remove the element by sliding out into the frypot and lifting up as you remove it.

6. Insert new element and reassemble in reverse order.



High-Limit Thermostat

Temperature

Sensor

Remove screws here.