Frymaster BK1814 User Manual

Page 23

Advertising
background image

Frymaster BK1814 Series Gas Fryers

Chapter 3: Installation

3-9

3.7 Electrical Connections

The fryer when installed must be electrically grounded in accordance with local codes, or in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70-(latest edition).


DANGER

This fryer is equipped with a three-prong (grounding) plug for protection against

electrical shock and must be plugged directly into a properly grounded, three-prong

receptacle. DO NOT CUT, REMOVE, OR OTHERWISE BYPASS THE GROUNDING

PRONG ON THIS PLUG!



The rating plate and wiring diagram are located inside the front door. The fryer is equipped with a
120VAC single-phase 60-hertz system (Domestic), or 230VAC single-phase 50-hertz system
(International/CE). Do not cut or remove the ground prong from the power cord plug. Do not
attempt to use the fryer during a power outage.

DANGER

This appliance requires electrical power for operation. Place the gas control valve in

the OFF position in case of a prolonged power outage. Do not attempt to operate

this appliance during a power outage.


Advertising