Frymaster 24G Series User Manual

Page 33

Advertising
background image

24G SERIES FLATBOTTOM GAS FRYERS

CHAPTER 4: FRYER OPERATIONS

4-4

4.1.1 Pilot Lighting Procedures, Standing Pilot (cont.)

7. Push and hold the knob in and apply a lighted match or taper to the pilot burner head. Continue

to hold the knob in for about 60 seconds after the flame appears on the pilot. Release the knob.
The pilot should remain lit.



4.1.2 Pilot Lighting Procedures, Electronic Ignition Systems

WARNING

Never use a match or taper to light pilot on this ignition system.

24V Gas Valves for Electronic Ignition: Rotate the knob counter-clockwise to the ON position.
Rotate the knob clockwise to turn the gas valve to OFF.




1. Turn gas valve knob to ON.

2. Turn electric power on with the appropriate rocker switch.

3. The ignition module will energize the pilot gas supply and the ignitor. The ignitor spark will

ignite the pilot gas. The presence of the pilot flame is then proved by a flame sensor, which
sends a signal to the main gas supply, opening the valve. The Thermatron controller controls the
fryer after ignition.

WARNING

In the event of prolonged power failure, the ignition module will shut down and lock out the

system. Turn the unit power "OFF" and then back "ON" after power has been re-

established.

4. If the pilot flame fails, the ignition module will shut down and lock out the system. To restart,

turn the electric power off, wait approximately 5 minutes for the system to recycle itself, then
turn the power on again. Repeat Steps 1-3.

Off position

On position

Advertising