Connector 4 – Firstech, LLC. CM4200 User Manual

Page 22

Advertising
background image

- 22 -

Pin 4 Violet/Black- Trunk-pin (-) negative input. This is an optional input that will

monitor when the vehicles trunk is opened. (Note: This wire will also trigger the
alarm when the system is armed.)


Pin 5 Red/White- Door trigger (-) negative input. This wire monitors (-) negative trigger

door-pins. The proper wire will provide a (-) negative trigger only when the doors
are opened. (Note: This wire is required for manual transmission remote starts.)


Pin 6 Red- Door trigger (+) positive input. This wire monitors (+) positive trigger door-

pins. The proper wire will provide a (+) positive trigger only when the doors are
opened. (Note: This wire is required for manual transmission remote starts.)


Pin 7 Brown/Black- Glow plug (-) negative input. This wire will delay the starter output

to allow the glow plugs to warm up on diesel engine vehicles. The proper wire will
only provide a (-) negative trigger while the “Wait to Start” light is on.


Pin 8 Brown/White- Glow plug (+) positive input. This wire will delay the starter output

to allow the glow plugs to warm up on diesel engine vehicles. The proper wire will
only provide a (+) positive trigger while the “Wait to Start” light is on.


Pin 9 Yellow/Black- Engine sensing input. A tach input or alternator input is required for

the system to sense when the vehicle is running. (Note: Option selected by
dipswitch #1. On=Tach sensing. Off=Alternator sensing.)

CONNECTOR 4


Pin 1 Not used

Pin 2 Violet/White- Trunk release 250mA (-) negative output. This wire will provide a

(-) negative trigger pulse. (Note: Positive trigger trunk release will require a relay.
System will unlock doors and disarm alarm prior to trunk release.)


Pin 3 Orange/Black- 2

nd

Unlock 250mA (-) negative output. This wire is an optional

output that will provide a (-) negative pulse output for driver’s priority door lock.
(Note: This feature will require additional relays and programming.)


Pin 4 Blue- Unlock 250mA (-) negative output. This wire will provide a (-) negative

pulse output during unlock and disarm. (Note: Positive and reverse polarity will
require additional relays.)


Pin 5 Blue/Black- Lock 250mA (-) negative output. This wire will provide a (-) negative

pulse output during lock and arm. (Note: Positive and reverse polarity will require
additional relays.