Connector 4, Pre-wired l.e.d.), Connector 5 – Firstech, LLC. CM4200 User Manual

Page 42: Pre-wired shock sensor), Connector 4 (pre-wired l.e.d.), Connector 5 (pre-wired shock sensor)

Advertising
background image

- 42 -

Pin 6 Light Blue/White- Brake 12-volts (+) positive input. This input is used for ignition

controlled door locks. The proper wire will test 12-volts (+) positive only when the
foot brake is pressed.


Pin 7 Black /White- Optional sensor (-) negative input. (Instant trigger)

CONNECTOR 4

(Pre-wired L.E.D.)


Pin 1 Black-L.E.D.- (-) negative output.

Pin 2 Black/White-3-volt L.E.D. (+) positive output.

CONNECTOR 5

(Pre-wired Shock Sensor)


Pin 1 Black-Shock sensor (-) negative ground input.

Pin 2 White-Shock sensor 2

nd

stage (-) negative input. (Instant trigger)


Pin 3 Red-Shock sensor 12-volt (+) positive input.

Pin 4 Yellow-Shock sensor 1

st

stage (-) negative input. (Warn away)



Advertising