LED Light

When shipped from the factory, the LED on the 45606 is set to turn

ON when the connected light is turned OFF. This allows the LED

to indicate the switch’s location in a dark room. To make the LED

turn ON when the light is turned ON, change parameter 3’s value

to “1”.
- Parameter No: 3
- Length: 1 Byte
- Valid Values = 0 or 1 (default 0)

Invert Switch

If the dimmer switch is accidentally installed upside down with

“On” at the bottom and “Off” at the top, the default On/Off rocker

settings can be reversed by changing parameter 4’s value to “1”.
- Parameter No: 4

- Length: 1 Byte
- Valid Values = 0 or 1 (default 0)

Dim Rate Adjustments

Both the number of steps (or levels) that the dimmer will change

and the timing of the steps can be modified to suit personal

preferences. The timing of the steps can be adjusted in 10

millisecond intervals. As an example, the default setting for

parameter 8 is “3”. This means that the lighting level will change

every 30 milliseconds when the Dim Command is received. A

value of 255 would mean that the level would change every

2.55 seconds. Combined, the two parameters allow dim rate

adjustments from 10 milliseconds to 4.2 minutes to go from

maximum-to-minimum or minimum-to-maximum

brightness levels.