Baud rate, Port 2 – GE Digital Video Multiplexer Recorder User Manual

Page 51

Advertising
background image

0150-0229D

51

Kalatel DVMRe StoreSafe

POTS Setup

SEQ key selects character bank
‘1’ key inserts blank character
‘2’ key inserts selected character

@ABCDEFGHIJKLMNOPQRSTUVWXYZ[\]^

Modem Init String : AT&

F1&K3M0E1Q0V1S0=0&R2&C1&D0&H1

POTS :

DISABLE

[Default Modem String] [CANCEL] [OK]

1. With the Modem Init String highlighted, press the Enter button to enter the Edit mode. The

character bank will appear in the center of the menu.

2. Press the Sequence button to select the desired character bank.

3. Rotate the Shuttle to navigate the Modem Init String.

4. Rotate the Jog to select a character from the character bank.

5. Use the Number 2 button or rotate the Shuttle to insert the desired character from the character

bank into the Modem Init String and advance to the next character.

6. Use the Number 1 button to insert a blank character.

7. When finished, press the Enter button.

8. To save the changes and reboot, select OK, then press the Enter button. The unit will only reboot

if changes were made to the Modem Init String.

9. To exit the menu without making changes, select Cancel, then press the Enter button. Pressing

the Menu button also exits the menu without making changes.

Baud Rate

Use this menu to configure the baud rate for Port 1 for external control
of the unit via RS232. Rotate the Jog to select a baud rate from the menu.

Save changes and exit the menu: Press the Enter button.

Exit the menu without making changes: Press the Menu button.

Port 2

Use this menu to configure the baud rate for Port 2. Rotate the
Jog to select a baud rate from the menu.

Save changes and exit the menu: Press the Enter button.

Exit the menu without making changes: Press the Menu button.

The RS232 port 2 is used for Event Generation and ASCII Text
Insertion. See Section 7 for the RS232 Protocol required to perform
these functions.

1200 Baud

2400 Baud

4800 Baud

19200 Baud

38400 Baud

57600 Baud

9600 Baud

1200 Baud

2400 Baud

4800 Baud

19200 Baud

38400 Baud

57600 Baud

9600 Baud

Advertising