14540

LC-1000 Lube System Controller

Sample LC-1000 Program for Series Progressive,

31 Point Series Progressive System

4. “CYCLE” (Cycle Switch Transitions)

a) Press “ENTER” Key; CYCLE

(switch transitions) blinks

b)

Use

S Key and X Key to select 20 (20

cycle switch transitions = 10 Divider cycles)

c) Press “ENTER” Key to accept value;

”PUMP” Icon blinks

5. “PUMP ON” (Pump Duty-Pulsed/Non-Pulsed)

a) Press “ENTER” Key –

“PUMP” (pulsed on time) blinks

b)

Use

S Key and X Key to set ” ON TIME”

TO 03 (3 sec pulsed output)

c) Press “ENTER” Key to accept value;

LCD returns to “DISPLAY” mode

Programming is now complete. To verify lube se-
quence, initiate a manual lube cycle by pressing
“MANUAL RUN” button.

NOTE

: If an electric motor driven pump or self cycling

barrel pump is used, enter “00” in Step 5b for

non-pulsed

output.

MASTER DIVIDER VALVE

LARGE BEARINGS

SECONDARY DIVIDER

VALVES

PUMP AND RESERVOIR

CYCLE SWITCH

DESCRIPTION

System Lube Volume: 6.0 cu in (99 cc) per hour
AL-50 Pump Used: .24 cu in per stroke (3.9 cc)
Master Divider Volume per Cycle: .15 cu in (2.4
cc)
Cycle Interval 15 Minute (1/4 hour) Used
Volume per Lube Cycle: 6.0 cu in/4 = 1.5 cu in/15
min.
Master Divider Cycles/Lube Cycle: 1.5 cu in/.15
cu in = 10 cycles
Cycle Switch Transitions (2 transitions/cycle) x 10
= 20
Pump Strokes per Lube Cycle: 1.5 cu in/.24 cu in
= 6.3 (use 7)
Monitor Time: 7 Strokes x 6 seconds/stroke (3
second "ON", 3 second "OFF") = 42 second x 2
(safety factor) = 84 seconds.

PROGRAMMING

1. Initiate Programming Mode

a) Press “PRGM” Key – “ON” Icon blinks

2. “ON” (Monitor Period)

a) Press “ENTER” Key – ON TIME/COUNT
blinks

b) Use S Key and X Key to set Monitor

(“ON”) Time to 0084

c) Press “ENTER” Key to accept value;
“SEC/MIN/HR/CNT”

blinks

d) Use S Key to scroll through choices;

select ” SEC”

e) Press “ENTER” Key to accept choice;

“OFF” Icon blinks

3. “OFF” (Pause Time)

a) Press “ENTER” Key –
OFF

TIME/COUNTblinks

b)

Use

S Key and X Key to set

“OFF TIME” to 0015

c) Press “ENTER" Key to accept value;
"SEC/MIN/HR/CNT"

blinks

d) Use S Key to scroll through choices;
select

“MIN”

e) Press “ENTER” Key to accept choice;

“CYCLE” Icon blinks