Jgp990sel, Ge profile, 30" downdraft gas cooktop – GE JGP990SEL User Manual

Page 2

Advertising
background image

For answers to your Monogram,

®

GE Profile

or

GE

®

appliance questions, visit our website at

ge.com or call GE Answer Center

®

service,

800.626.2000.

Listed by

Underwriters

Laboratories

R

Installing the Ductwork: Use galvanized
or aluminum duct in 6” round or 3-1/4” x
10” size, or combination of both.

PVC duct

or locally approved piping should be used

if installing under a poured concrete slab.
Local building code must be followed in
specifying type and schedule of all duct used.
Note: Ductwork must be vented to outside.
Do not vent into a wall, ceiling, crawlspace,
attic or any concealed space. Always use
an appropriate roof or wall cap with damper.

Laundry-type wall caps should never

be used. For maximum efficiency use the
shortest and straightest duct run possible,
with as few fittings as possible.
For satisfactory performance the duct run
should not exceed 100 feet equivalent length.
Refer to the table of equivalent lengths
(shown in installation instructions) for
various duct configurations.

Venting Options

Through Cabinet Toe Space

Inside Wall to Roof

Direct to Outside

Between Floor Joist

Specification Created 12/05

230281

JGP990SEL

GE Profile

30" Downdraft Gas Cooktop

Dimensions and Installation Information (in inches)

Advertising