Model GGH2O

®

Using the Uni-Strut - Option #2

1. The uni-strut (supplied by others) that holds the

hood up cantilevers over the end of the hood and
is mounted to the supply plenum hanger brackets.

ATTACHED AIR CURTAIN CANOPY STYLE HOOD

ATTACHED AIR CURTAIN CANOPY STYLE HOOD

BACKSUPPLY BACKSHELF HOOD

BACKSUPPLY CANOPY STYLE HOOD

BACKSUPPLY CANOPY STYLE HOOD

VARIABLE SUPPLY PLENUM CANOPY STYLE HOOD

Air Curtain Supply Plenum

(ASP)

ATTACHED AIR CURTAIN CANOPY STYLE HOOD

ATTACHED AIR CURTAIN CANOPY STYLE HOOD

BACKSUPPLY BACKSHELF HOOD

BACKSUPPLY CANOPY STYLE HOOD

BACKSUPPLY CANOPY STYLE HOOD

VARIABLE SUPPLY PLENUM CANOPY STYLE HOOD

Variable Supply Plenum

(HSP or VSP)

Using the Threaded Rod - Option #3

1. Insert 1/2 in. (12.7 mm) diameter threaded rod (by

others) into hanger brackets on the supply plenum
top. Raise and hang the external supply plenum
from adequate roof or ceiling supports.

2. The external supply plenum should be resting

lightly against the hood. The hood is used to
position the plenum only, it is not intended to
support the plenum. All hanger brackets must be
used and the plenum must be properly supported
while lifting to prevent damage or distortion. The
supply plenum must be hung level to operate
properly.

(Optional fastening of supply plenum to hood. See
directions).

3. It is recommended that caulk be applied at the

mating seams and surfaces of the plenum, the
hood, and the wall. If the supply plenum is next
to a wall, you will also need to caulk around the
surface next to the wall. Caulk the joints with
NSF Approved silicone caulk (GE SCS1000, or its
equivalent). The caulk is not provided.

Installing the Supply Duct Collar to the

Plenum

1. Place the duct collar(s) over the opening, fastening

with tack-welds at 1 to 2 in. (2.54 to 5.08 cm)
intervals, or sheet metal screws at 3 to 6 in.
(7.62 to 15.24 cm) intervals.

External Supply Plenum Weights, Dimensions and Supply Rates

External Supply

Plenum Type

Weight

Width

Height

Length per

section

Recommended

Supply Rate

(lbs/ft)

(kg/ft)

(in)

(mm)

(in)

(mm)

(ft)

(m)

Back Supply

35.0

15.878

6

152.4 Variable Variable 3 to 16 .91 to

4.88

145 cfm/ft

(246.36 m

3

/hr)

Air Curtain Supply

• 14 inch

9.5

4.31

14

355.6

10

254

3 to 16 .91 to

4.88

110 cfm/ft

(186.89 m

3

/hr)

Air Curtain Supply

• 24 inch

12.5

5.67

24

609.6

10

254

3 to 16 .91 to

4.88

145 cfm/ft

(246.36 m

3

/hr)

Variable Supply

16.0

7.26

12

304.8

18

457.20 3 to 16 .91 to

4.88

curtain

0-80 cfm/ft

(0-135.92 m

3

/hr)

face

80-160 cfm/ft

(135.92 -271.84 m

3

/hr)

Horizontal Supply

14.0

6.35

12

304.8

18

457.20 3 to 16 .91 to

4.88

150 cfm/ft

(254.85 m

3

/hr)

Hood

UTILITY

CABINET

TOP VIEW

HOOD

TOP VIEW

SUPPLY PLENUM

SUPPLY PLENUM SHELL

END VIEW

HOOD FRONT

Option #2
Uni-Strut supplied by others

Option #3
Threaded Rod
supplied by others

Threaded Rod

‘C’ Clamp

Hood Standing Seam

Hanging Clip bolted to plenum shell

Hanging Clip

Option #2
The uni-strut (U channel) that holds the hood up,
cantilevers over the end of the hood and is
mounted to the Air Curtain Supply Plenum (ASP)
hanger brackets

Option #1
For plenums < than or = 96 inches
Two (2) clips are needed.

For plenums > than 96 inches
Three (3) clips are needed.

The third clip is located in the
center of the plenum length.

Option #1
Attach hanging clip to hood
standing seam with the
supplied ‘C’ clamps.
Optional: Drill and bolt a

1/4-20 SS bolt through the
clip and hood standing seam

Option #1

Hanging clip could be 23.5 inches from end if there is a utility cabinet on the
end of the hood.

Option #1 : Hanging Clip

Hanger Bracket

Note: Supply plenums are standardly supplied with hanging clips (Option #1).

If Option #1 is not applicable, use Options #2 or #3

Hanging methods for supply plenums

ASP: Air Curtain Supply Plenum

FSP: Face Supply Plenum

VSP: Variable Supply Plenum

Option #1: Hanging Clip

Option #2: Uni-Strut

Option #3: Threaded Rod

11.5

23.5

Hanger Bracket

Exhaust Plenum

Duct cut out area

Duct cut out area

Hood Length

Hood

Width

Exhaust Duct

Connection

Exhaust duct connection is to be

a continuous liquid-tight weld to hood.

Supply Duct

Connection

Supply duct connection to be
tack-welded with 1 to 2 inch
tacks or sheet metal screws
at 3 to 6 inch spacing to hood.

Front of Hood

Exhaust Plenum

8.0

8.0

8.0

3.0

3.0

14.0

8.0

1.0

12.0

NOTE: 1. Exhaust duct connection to be located within 48 inches from center of hood length to center of duct connection.

2. UL Listed hood assembly to be used only with Greenheck Fan Corp. labelled subassembly for exhaust hood without exhaust damper part no. DC

TOP VIEW

BACK VIEW

Top of Hood

Dimensions are shown in inches.