Galaxy Metal Gear 65 User Manual

Page 147

Advertising
background image

Managing Arrays & Partitions

127

The number of drives you can add to an array depends upon the RAID level as shown in

Table 3–2

. You

also cannot exceed the maximum number of drives for each RAID level. See

C.1, ”Creating Arrays”, on

page 105

.

If you are expanding a multiple-partition array, you add free space at the end of the array. For more
information about partitions, see

C.3.1, ”Understanding Partitions”, on page 133

.

Note

Once you start expanding array capacity, you cannot stop it. The expand function may take an hour or
more to complete, depending on the array type, array size, drive speed, and other processes running on
the Galaxy 65 Subsystem.

To expand an array:

1

From the System Menu, select Array Menu and press Enter.
The Select Array screen displays with a list of existing arrays.

2

Select the array you want and press Enter.
The array menu displays.

3

Select Expand Function and press Enter
.The expand menu displays.

4

Select Start Expand and press Enter
The Number of Drives screen displays.

Table 3–2

Drive additions by RAID level

RAID level

Number of drives you can add

Maximum

number of drives

RAID 0

1 to 4 at a time up to the maximum

16

RAID 1 (Mirrored)

Cannot expand

N/A

Volume Set

Cannot expand

N/A

RAID 10

2 or 4 at a time up to the maximum

16

RAID 3, 4, or 5

1 to 4 at a time up to the maximum

16

RAID 50

You can expand the array, one RAID 5 array at a time up to the
maximum number of drives. All RAID 5 arrays must contain the
same number of drives.

32

Advertising