Gossen MetraWatt 702 User Manual
Page 41

GOSSEN METRAWATT GMBH
41
Multimeter Measurements for Devices with Feature F01
Reference Ranges
Line Voltage
230 V
±0.2%
Line Frequency
50 Hz
±0.1%
Waveshape
Sine (deviation between effective and rectified
value < 0.5%)
Ambient Temperature
+23
°C ±2 K
Relative Humidity
40
… 60%
Load Resistance
Linear
Nominal Ranges of Use
Line Voltage
207 V
… 253 V
Line Frequency
50 Hz
Line Voltage
Waveshape
Sine
Temperature
0
°C … + 50 °C
Ambient Conditions
Storage Temperature
– 20
°C ... + 60 °C
Operating Temperature – 10
°C ... + 50 °C
Accuracy Range
0
°C ... + 50 °C
Relative Humidity
Max. 75%, no condensation allowed
Elevation
Max. 2000 m
Deployment
Indoors, except within specified ambient
conditions
Influencing Quantities and Influence Error
Func-
tion
Measured Quantity Measuring Range /
Nominal Range of
Use
Reso-
lution
Open-
Circuit
Voltage
U
0
Short-
Circuit
Current
I
K
Internal
Resis-
tance
R
I
Measuring
Error
Intrinsic Error
Overload Capacity
Value
Duration
U
AC/DC
Voltage
0 ... 253.0 V
,
and
0.1 V
—
—
—
—
±
(2.5 % rdg. +5 d)
> 10 d
253 V
cont.
Low Voltage, SC III
±
(5% rdg. +10 d)
R
Resistance
0 ... 150.0 k
Ω
100
Ω
< 20 V –
1.1 mA
—
—
±
(1% rdg. +3 d)
253 V
cont.
I
Clip
Current with
Clip-On Current-
Voltage Transformer
WZ12C
0.000 ... 10.00 A
1 mA
—
—
1.5 M
Ω
—
±
(3% rdg. +10 d)
> 10 d
without clip-on device
253 V
cont.
0 ... 100 A
1 A
—
—
1.5 M
Ω
—
253 V
cont.
Temp.
Temperature
with Pt100/Pt1000
Sensor
– 200 ... – 50
°
C
1
°
C
< 20 V –
1.1 mA
—
—
±
(2% rdg. +1
°
C)
10 V
cont.
– 50.1 ... + 300.0
°
C
0.1
°
C
±
(1% rdg. +1
°
C)
10 V
cont.
+300 ... +850
°
C
1
°
C
±
(2% rdg. +1
°
C)
10 V
cont.
Influencing Quantity /
Sphere of Influence
Designation
per
DIN VDE 0404
Influence Error
± … % of Measured Value
Position Change
E1
—
Change in Test Setup Supply Power
E2
2.5
Temperature Fluctuation
E3
Specified influence error applies per
10 K change in temperature:
0
… 21
°
C and 25
… 40
°
C
1 in case of PE measurement
0.5 for all other measuring ranges
Current at Device Under Test
E4
2.5
Low-Frequency Magnetic Fields
E5
2.5
Impedance at Device Under Test
E6
2.5
Capacitance, Insulation Measurement
E7
2.5
Waveshape of Measured Current
E8
49
… 51 Hz
2 for capacitive load (for equivalent
leakage current)
45
… 100 Hz
1 (for contact current)
2.5 for all other measuring ranges